THE FLEXIBLE PATIENT MONITOR – PRIZM 3
OPTIONS AVAILABLE
- NIBP, SPO2 & PULSE
- SPO2 & PULSE
- NIBP, SPO2, TEMP & ECG
PRIZM3 – This advanced pulse oximeter offers fast and reliable Sp02, Pulse Rate and ECG with waveform and trend display. The alarm system for NIBP, Temp and ECG makes it easy to monitor a patient. Its built-in battery lasts for more than 3 hours and makes the PRIZM ES the first choice for hospital and patient transport by ambulance.
Description
MODEL: | PRIZM3 |
Display Type: Resolution: Waveform Type: Indicator: Display data: |
Mono Graphic LCD 240 x 64 pixels ECG Leads AC Power or Battery operated indicators Sp02, HR(PR), SYS, DIA, MEAN, TEMP, Battery Status, PI, ECG channel, alarm status |
Trends Memory: Display |
15 days at 10 second interval Tabular |
Interface | S/W Upgrade: RS-232 |
PHYSICAL DIMENSIONS | |
Dimensions | 850(H) X 245(W) x 840(D)mm |
Weight | 1,200g |
Alarms |
– Audible and visual alarms (Sp02, PR, HR, SYS, DIA, MEAN, TEMP) – Low battery, ECG lead off, Sp02 finger off, system error – Silence : 2 minutes – Volume: 0(off) ~ 7 |
ENVIRONMENTAL CONDITIONS | |
Temperature Operating: Storage: |
5 to 40 (41 to 104) -20 to 60 (-4 to 140) |
Humidity Operating: Storage: |
15 to 95%, non-condensing 10 to 95%, non-condensing |
PERFORMANCE | |
ECG Leads Display Sensitivity: Gain Selection: Frequency Response: Sweep Speed: Pacemaker Detection: Heart Rate Range: Heart Rate Accuracy: |
3 leads 1.0cm/mV ± 10% X0.25, X0.5, x1, x2 0.5 to 40Hz 25mm/sec, 50mm/sec Yes 0 to 300bpm ± 3% or ± 3bpm whichever is greater |
Pulse Oximetry (SPO2) Measurement Range:
Accuracy:
SPO2 Technology |
Sp02 0% – 100% Pulse Rate – 15 to 300bpm Sp02 – 70 to 100% ± 2%, 0 to 69% – unspecified Pulse Rate – 15 to 300bpm ± 3bpm
Nellcor compatible |
Temperature Measurement Range: Accuracy:
Probe Type: |
15 to 45 (59 to 113) ±0.1 (25 to 45)9 ±0.2 (15 to 24) Compatible with YSI 400 series |
NIBP Technique:
Cuff Pressure Range: Pressure Accuracy: Static: Clinical: Pulse Rate Measurement range: Inflation Time for cuff: Total cycle time:
Intervals for Auto: Overpressure Protection: Adult: Pediatric: Neonate: |
Oscillometric Adult – SYS 30 to 270mmHG DIA 10 to 220mmHG MEAN 20 to 235mmHG Child – SYS 30 to 235mmHG DIA 10 to 220mmHG MEAN 20 to 225mmHG Neonate – SYS 30 to 135mmHG DIA 10 to 110mmHG MEAN 20 to 125mmHG 0 to 280mmHg ±2% or 3mmHg, whichever is greater ± 5mmHg average error 8mmHg standard deviation 40 ~ 240bpm Less than 40 sec. (standard adult cuff) 20 to 45 seconds typical (depend on heart rate and motion artifact) 5,10,15,13,60,90,120,240,480,960 minutes Hardware and software double protections] 315±10mmHg 265±10mmHg 155±10mmHg |
ELECTRICAL RATINGS | |
Main Machine Input Voltage: Power Consumption: Fuse Rating: |
100-240VAC, 50/60Hz 24 VA 1 Amp, 250V |
Power Supply | Output DC12V |
Battery Type: Battery Running Time: |
NI-MH 2 hours |