PRIZM3 – This advanced pulse oximeter offers fast and reliable Sp02, Pulse Rate and ECG with waveform and trend display.  The alarm system for NIBP, Temp and ECG makes it easy to monitor a patient.   Its built-in battery lasts for more than 3 hours and makes the PRIZM ES the first choice for hospital and patient transport by ambulance.

Compare

Description

MODEL: PRIZM3

Display

Type:

Resolution:

Waveform Type:

Indicator:

Display data:

 

Mono Graphic LCD

240 x 64 pixels

ECG Leads

AC Power or Battery operated indicators

Sp02, HR(PR), SYS, DIA, MEAN, TEMP, Battery Status, PI, ECG channel, alarm status

Trends

Memory:

Display

 

15 days at 10 second interval

Tabular

Interface S/W Upgrade: RS-232
PHYSICAL DIMENSIONS
Dimensions 850(H) X 245(W) x 840(D)mm
Weight 1,200g
Alarms

–        Audible and visual alarms (Sp02, PR, HR, SYS, DIA, MEAN, TEMP)

–        Low battery, ECG lead off, Sp02 finger off, system error

–        Silence : 2 minutes

–        Volume: 0(off) ~ 7

ENVIRONMENTAL CONDITIONS

Temperature

Operating:

Storage:

 

5 to 40 (41 to 104)

-20 to 60 (-4 to 140)

Humidity

Operating:

Storage:

 

15 to 95%, non-condensing

10 to 95%, non-condensing

PERFORMANCE

ECG

Leads

Display Sensitivity:

Gain Selection:

Frequency Response:

Sweep Speed:

Pacemaker Detection:

Heart Rate Range:

Heart Rate Accuracy:

 

3 leads

1.0cm/mV ± 10%

X0.25, X0.5, x1, x2

0.5 to 40Hz

25mm/sec, 50mm/sec

Yes

0 to 300bpm

± 3% or ± 3bpm whichever is greater

Pulse Oximetry (SPO2)

Measurement Range:

 

Accuracy:

 

 

SPO2 Technology

 

Sp02 0% – 100%

Pulse Rate –  15 to 300bpm

Sp02 – 70 to 100% ± 2%, 0 to 69% – unspecified

Pulse Rate – 15 to 300bpm ± 3bpm

 

Nellcor compatible

Temperature

Measurement Range:

Accuracy:

 

Probe Type:

 

15 to 45 (59 to 113)

±0.1 (25 to 45)9

±0.2 (15 to 24)

Compatible with YSI 400 series

NIBP

Technique:

 

 

 

 

 

 

 

 

 

Cuff Pressure Range:

Pressure Accuracy:

Static:

Clinical:

Pulse Rate Measurement range:

Inflation Time for cuff:

Total cycle time:

 

Intervals for Auto:

Overpressure Protection:

Adult:

Pediatric:

Neonate:

 

Oscillometric

Adult –      SYS     30 to 270mmHG

DIA      10  to 220mmHG

MEAN  20 to 235mmHG

Child –      SYS     30 to 235mmHG

DIA      10  to 220mmHG

MEAN  20 to 225mmHG

Neonate – SYS     30 to 135mmHG

DIA      10  to 110mmHG

MEAN  20 to 125mmHG

0 to 280mmHg

±2% or 3mmHg, whichever is greater

± 5mmHg average error

8mmHg standard deviation

40 ~ 240bpm

Less than 40 sec. (standard adult cuff)

20 to 45 seconds typical (depend on heart rate and motion artifact)

5,10,15,13,60,90,120,240,480,960 minutes

Hardware and software double protections]

315±10mmHg

265±10mmHg

155±10mmHg

ELECTRICAL RATINGS

Main Machine

Input Voltage:

Power Consumption:

Fuse Rating:

 

100-240VAC, 50/60Hz

24 VA

1 Amp, 250V

Power Supply Output DC12V

Battery

Type:

Battery Running Time:

NI-MH

2 hours

 

X